CKD: Nutritional Status: Technical Devices and Anthropometric Measures (2018)

Author and Year:
Furstenberg A and Davenport A 2011
PubMed ID:
Article Title:
Comparison of multifrequency bioelectrical impedance analysis and dual-energy X-ray absorptiometry assessments in outpatient hemodialysis patients.
Authors:
Fürstenberg A, Davenport A
Journal:
American Journal of Kidney Diseases : the official journal of the National Kidney Foundation
Year of publication:
2011
Volume:
57
Issue:
1
Page numbers:
123-9
Study Design:
Diagnostic, Validity or Reliability Study
Risk of Bias Assessment Rating:
Positive
Inclusion Criteria:
Attending Royal Free Hospital dialysis center; HD three times per week; Annual DXA measurement available; Post dialysis multi-frequency BIA (mf-BIA) measurement available for dry weight assessment
Exclusion Criteria:
Implantable defibrillators; Cardiac pacemaker; Amputee
Research Purpose:
To determine retrospectively the reliability of multifrequency BIA in assessing the nutritional status of HD patients
Blinding efforts:
Not Reported
Study Location:
London, UK
Source(s) of Funding:
University/Hospital
Please specify names of funders:
University College London Medical School
Quality Criteria Checklist: Primary Research
Relevance Questions
  1. Would implementing the studied intervention or procedure (if found successful) result in improved outcomes for the patients/clients/population group? (Not Applicable for some epidemiological studies) Yes
  2. Did the authors study an outcome (dependent variable) or topic that the patients/clients/population group would care about? Yes
  3. Is the focus of the intervention or procedure (independent variable) or topic of study a common issue of concern to dieteticspractice? Yes
  4. Is the intervention or procedure feasible? (NA for some epidemiological studies) Yes
 
Validity Questions
1. Was the research question clearly stated? Yes
  1.1. Was (were) the specific intervention(s) or procedure(s) [independent variable(s)] identified? Yes
  1.2. Was (were) the outcome(s) [dependent variable(s)] clearly indicated? Yes
  1.3. Were the target population and setting specified? Yes
2. Was the selection of study subjects/patients free from bias? ???
  2.1. Were inclusion/exclusion criteria specified (e.g., risk, point in disease progression, diagnostic or prognosis criteria), and with sufficient detail and without omitting criteria critical to the study? No
  2.2. Were criteria applied equally to all study groups? N/A
  2.3. Were health, demographics, and other characteristics of subjects described? Yes
  2.4. Were the subjects/patients a representative sample of the relevant population? ???
3. Were study groups comparable? Yes
  3.1. Was the method of assigning subjects/patients to groups described and unbiased? (Method of randomization identified if RCT) N/A
  3.2. Were distribution of disease status, prognostic factors, and other factors (e.g., demographics) similar across study groups at baseline? N/A
  3.3. Were concurrent controls or comparisons used? (Concurrent preferred over historical control or comparison groups.) N/A
  3.6. If diagnostic test, was there an independent blind comparison with an appropriate reference standard (e.g., "gold standard")? Yes
4. Was method of handling withdrawals described? Yes
  4.1. Were follow-up methods described and the same for all groups? Yes
  4.2. Was the number, characteristics of withdrawals (i.e., dropouts, lost to follow up, attrition rate) and/or response rate (cross-sectional studies) described for each group? (Follow up goal for a strong study is 80%.) N/A
  4.3. Were all enrolled subjects/patients (in the original sample) accounted for? Yes
  4.5. If diagnostic test, was decision to perform reference test not dependent on results of test under study? Yes
5. Was blinding used to prevent introduction of bias? Yes
  5.2. Were data collectors blinded for outcomes assessment? (If outcome is measured using an objective test, such as a lab value, this criterion is assumed to be met.) Yes
  5.5. In diagnostic study, were test results blinded to patient history and other test results? ???
6. Were intervention/therapeutic regimens/exposure factor or procedure and any comparison(s) described in detail? Were interveningfactors described? Yes
  6.2. In observational study, were interventions, study settings, and clinicians/provider described? Yes
  6.3. Was the intensity and duration of the intervention or exposure factor sufficient to produce a meaningful effect? N/A
  6.8. In diagnostic study, were details of test administration and replication sufficient? Yes
7. Were outcomes clearly defined and the measurements valid and reliable? ???
  7.2. Were nutrition measures appropriate to question and outcomes of concern? Yes
  7.4. Were the observations and measurements based on standard, valid, and reliable data collection instruments/tests/procedures? Yes
  7.5. Was the measurement of effect at an appropriate level of precision? ???
  7.6. Were other factors accounted for (measured) that could affect outcomes? ???
  7.7. Were the measurements conducted consistently across groups? N/A
8. Was the statistical analysis appropriate for the study design and type of outcome indicators? Yes
  8.1. Were statistical analyses adequately described and the results reported appropriately? Yes
  8.2. Were correct statistical tests used and assumptions of test not violated? Yes
  8.3. Were statistics reported with levels of significance and/or confidence intervals? Yes
  8.4. Was "intent to treat" analysis of outcomes done (and as appropriate, was there an analysis of outcomes for those maximally exposed or a dose-response analysis)? No
  8.5. Were adequate adjustments made for effects of confounding factors that might have affected the outcomes (e.g., multivariate analyses)? No
  8.6. Was clinical significance as well as statistical significance reported? Yes
  8.7. If negative findings, was a power calculation reported to address type 2 error? No
9. Are conclusions supported by results with biases and limitations taken into consideration? Yes
  9.1. Is there a discussion of findings? Yes
  9.2. Are biases and study limitations identified and discussed? Yes
10. Is bias due to study's funding or sponsorship unlikely? Yes
  10.1. Were sources of funding and investigators' affiliations described? Yes
  10.2. Was the study free from apparent conflict of interest? Yes