CKD: Nutritional Status: Technical Devices and Anthropometric Measures (2018)
Author and Year:
Stall S et al 1996
PubMed ID:
Article Title:
Comparison of five body-composition methods in peritoneal dialysis patients.
Authors:
Stall S, Ginsberg N, DeVita M, Zabetakis P, Lynn R, Gleim G, Wang J, Pierson R, Michelis M
Journal:
The American Journal of Clinical Nutrition
Year of publication:
1996
Volume:
64
Issue:
2
Page numbers:
125-30
Study Design:
Case Control Study
Risk of Bias Assessment Rating:
Neutral
Inclusion Criteria:
Patient at the Sol Goldman Renal Therapy Center, Lenox Hill Hospital, NY or Baumritter Kidney Center, Albert Einstein College of Medicine, Bronx, NY; Receiving peritoneal dialysis; Stable; No hospitalizations or episodes of peritonitis within one month of study; Informed consent.
Control group: age, race, sex, height, weight, and BMI matched to PD patients from a large existing pool of control data obtained previously in the Body Composition Unit
Exclusion Criteria:
Not Reported
Research Purpose:
To compare five methods of estimating fat and/or FFM in stable peritoneal dialysis patients and then to compare these results with those of matched normal laboratory control subjects. The five modalities used were BIA, TBK, DXA, and two anthropometric equations that are based on different measurements.
Blinding efforts:
Not Reported
Study Location:
New York, NY
Source(s) of Funding:
University/Hospital, Not-for-profit
Please specify names of funders:
Authors affiliated with the Sol Goldman Renal Therapy Center, Lenox Hill Hospital, NY; Baumritter Kidney Center, Albert Einstein College of Medicine, Bronx, NY; Body Composition Unit, St. Luke''s-Roosevelt Hospital Center, Columbia University, NY
National Kidney Foundation
Quality Criteria Checklist: Primary Research
|
|||
Relevance Questions | |||
1. | Would implementing the studied intervention or procedure (if found successful) result in improved outcomes for the patients/clients/population group? (Not Applicable for some epidemiological studies) | Yes | |
2. | Did the authors study an outcome (dependent variable) or topic that the patients/clients/population group would care about? | Yes | |
3. | Is the focus of the intervention or procedure (independent variable) or topic of study a common issue of concern to dieteticspractice? | Yes | |
4. | Is the intervention or procedure feasible? (NA for some epidemiological studies) | Yes | |
Validity Questions | |||
1. | Was the research question clearly stated? | Yes | |
1.1. | Was (were) the specific intervention(s) or procedure(s) [independent variable(s)] identified? | Yes | |
1.2. | Was (were) the outcome(s) [dependent variable(s)] clearly indicated? | Yes | |
1.3. | Were the target population and setting specified? | Yes | |
2. | Was the selection of study subjects/patients free from bias? | ??? | |
2.1. | Were inclusion/exclusion criteria specified (e.g., risk, point in disease progression, diagnostic or prognosis criteria), and with sufficient detail and without omitting criteria critical to the study? | No | |
2.2. | Were criteria applied equally to all study groups? | N/A | |
2.3. | Were health, demographics, and other characteristics of subjects described? | Yes | |
2.4. | Were the subjects/patients a representative sample of the relevant population? | ??? | |
3. | Were study groups comparable? | ??? | |
3.1. | Was the method of assigning subjects/patients to groups described and unbiased? (Method of randomization identified if RCT) | Yes | |
3.2. | Were distribution of disease status, prognostic factors, and other factors (e.g., demographics) similar across study groups at baseline? | ??? | |
3.3. | Were concurrent controls or comparisons used? (Concurrent preferred over historical control or comparison groups.) | Yes | |
3.5. | If case control study, were potential confounding factors comparable for cases and controls? (If case series or trial with subjects serving as own control, this criterion is not applicable.) | ??? | |
4. | Was method of handling withdrawals described? | Yes | |
4.1. | Were follow-up methods described and the same for all groups? | N/A | |
4.2. | Was the number, characteristics of withdrawals (i.e., dropouts, lost to follow up, attrition rate) and/or response rate (cross-sectional studies) described for each group? (Follow up goal for a strong study is 80%.) | Yes | |
4.3. | Were all enrolled subjects/patients (in the original sample) accounted for? | Yes | |
5. | Was blinding used to prevent introduction of bias? | Yes | |
5.2. | Were data collectors blinded for outcomes assessment? (If outcome is measured using an objective test, such as a lab value, this criterion is assumed to be met.) | No | |
5.4. | In case control study, was case definition explicit and case ascertainment not influenced by exposure status? | Yes | |
6. | Were intervention/therapeutic regimens/exposure factor or procedure and any comparison(s) described in detail? Were interveningfactors described? | Yes | |
6.1. | In RCT or other intervention trial, were protocols described for all regimens studied? | N/A | |
6.3. | Was the intensity and duration of the intervention or exposure factor sufficient to produce a meaningful effect? | Yes | |
6.4. | Was the amount of exposure and, if relevant, subject/patient compliance measured? | Yes | |
6.5. | Were co-interventions (e.g., ancillary treatments, other therapies) described? | No | |
6.6. | Were extra or unplanned treatments described? | N/A | |
6.7. | Was the information for 6.4, 6.5, and 6.6 assessed the same way for all groups? | N/A | |
7. | Were outcomes clearly defined and the measurements valid and reliable? | Yes | |
7.1. | Were primary and secondary endpoints described and relevant to the question? | Yes | |
7.2. | Were nutrition measures appropriate to question and outcomes of concern? | Yes | |
7.3. | Was the period of follow-up long enough for important outcome(s) to occur? | Yes | |
7.4. | Were the observations and measurements based on standard, valid, and reliable data collection instruments/tests/procedures? | Yes | |
7.5. | Was the measurement of effect at an appropriate level of precision? | Yes | |
7.6. | Were other factors accounted for (measured) that could affect outcomes? | Yes | |
7.7. | Were the measurements conducted consistently across groups? | Yes | |
8. | Was the statistical analysis appropriate for the study design and type of outcome indicators? | Yes | |
8.1. | Were statistical analyses adequately described and the results reported appropriately? | Yes | |
8.2. | Were correct statistical tests used and assumptions of test not violated? | Yes | |
8.3. | Were statistics reported with levels of significance and/or confidence intervals? | Yes | |
8.4. | Was "intent to treat" analysis of outcomes done (and as appropriate, was there an analysis of outcomes for those maximally exposed or a dose-response analysis)? | Yes | |
8.5. | Were adequate adjustments made for effects of confounding factors that might have affected the outcomes (e.g., multivariate analyses)? | ??? | |
8.6. | Was clinical significance as well as statistical significance reported? | Yes | |
8.7. | If negative findings, was a power calculation reported to address type 2 error? | No | |
9. | Are conclusions supported by results with biases and limitations taken into consideration? | Yes | |
9.1. | Is there a discussion of findings? | Yes | |
9.2. | Are biases and study limitations identified and discussed? | No | |
10. | Is bias due to study's funding or sponsorship unlikely? | Yes | |
10.1. | Were sources of funding and investigators' affiliations described? | Yes | |
10.2. | Was the study free from apparent conflict of interest? | Yes | |